With micro-fuel-cell: measuring ranges 0 ... 25 vol-% and 0 ... 1ppm; EEx for zone 1; specific sensors e.g. for measuring in nearly 100% Hydrogen; components for process applications; 2-channel-instruments With Zirconia sensor: measuring ranges 0,1..1ppm until 0..40 vol-% wall mounting, desktop and 19“-slide-in for all detectors
Applications:
With micro-fuel-cell: O2-measurement e.g. in industrial gases as well as in complex gas mixtures; quick O2-analysis from 20 vol-% down to 2ppm within 20 minutes time. With Zirconia sensor: Zirconia sensor for inert gases and for gases with combustibles
ZrO2-Probes for Oxygen
Series 3200
Summary:
Range of probe lengths from 150 mm to 3 m Gas temperatures up to 1750°C EEx d II B+H2 -probe for zone 1; electronic controller Measuring ranges: 0,2 to 25 vol-% O2, 1ppm to 100 vol-% O2
Applications:
Oxygen measurement in flue gases and for the control of combustion processes certified systems based on the 13. and 17.BImSchV and TA Luft
Detection Systems for Toxic Gases TOXITRACE
Series 6400
Summary:
Monitoring maximum gas concentration at the working place (TLV), 2-wire transmitter, online signal recording, low concentrations detectable down to 0,1 ppm, micro-fuel-cell detector, changing of electrolyte not necessary
3 systems, customized system design, PTB-approved for custody transfer, burner or catalytic reactor to oxidise the probe gas, ZrO2-sensor for residual Oxygen measurement, continuous process application, 19“-slide-in and HF1 cabinet
Applications:
Wobbe Index, Air Demand, Specific Gravity and Calorific Value in combustion gases; measurements in hazardous zone 2, T3, suitable for H2; for normally not flammable gases the CAT-model with catalytic reactor
Catalytic Air Cleaner
Series 8100
Summary:
Catalytic oxidation, 2 different catalysts: Pt or Pt/Pd, protective design according to EEx p IIC T3 for zone 2, 19“-slide-in, desktop or field instrument
Applications :
Generating hydrocarbon- and carbon-monoxide-free combustion air or zero gas
Process Refractometer
Summary:
Online determination of the refraction index of fluids measured at total refraction, independent of solid particle content and turbidity, direct process pipe mounting, light pipe technique for signal processing allows 200°C probe temperature
Applications:
Continuous analysis of binary and quasi-binary liquids of NaOH, HCl, sulphuric acid a.o.